- Электронная почта
- Телефон
-
Адрес
No. 299 Jincheng East Road, Wuzhou International Industrial Expo City
Wuxi Kaiweilian Hydraulic Machinery Co., Ltd
No. 299 Jincheng East Road, Wuzhou International Industrial Expo City
ZDR10DA1-40B/210YM, Stacked pressure reducing valve
ZDRStacked direct acting pressure reducing valve
6/10:胖 taking the reinsurance of in perpetuity; of 06 ( 6 mm ) / by 10 ( 10 mm )( ISO 4401 )
D: Direct acting type
AThe pressure reducing oil port isA→A1(A port decompression)
1Adjustment method=Knob type (lockable, with scale)
40B40 series, B-type seal (size unchanged)
210:Maximum regulated pressure of 21MPa (210bar)
Y: Control oilinner supply
M:Built in one-way valve (A1 → A reverse cutoff)
| parameter | ZDR6DA1-40B/210YM | ZDR10DA1-40B/210YM |
|---|---|---|
| path | NG06(6mm) | NG10(10mm) |
| Installation method | Stacked (plate type) | Stacked (plate type) |
| mounting surface | ISO4401-03 / DIN24340 A 型 | ISO4401-05 / DIN24340 A 型 |
| maximum flow | 50 L/min | 80 L/min |
| voltage regulation range | 1.0~21.0 MPa | 1.0~21.0 MPa |
| Maximum withstand voltage (A port) | 31.5 MPa | 31.5 MPa |
| Export pressure resistance (A1) | 21.0 MPa | 21.0 MPa |
| Return oil pressure resistance (T port) | ≤10 MPa | ≤10 MPa |
| adjustment method | Knob (lockable, with scale) | Knob (lockable, with scale) |
| Sealing material | Nitrile rubber (NBR) | Nitrile rubber (NBR) |
| medium | Ordinary/anti-wear hydraulic oil (HLP32-68) | Ordinary/anti-wear hydraulic oil (HLP32-68) |
| oil temperature | -20℃~+60℃ | -20℃~+60℃ |
| weight | About 0.8 kg | About 1.5 kg |
normal stateThe valve core is normally open,A → A1 free flow, one-way valve conducting;
Reduce pressure and stabilize voltageA1 pressure rises to the set value → valve core balance → decrease A → A1 opening → pressure drop increases →A1 stabilizes at the set pressure;
Overflow protectionA1 overpressure → valve core movement →A1 → T connection overflowLimit A1 to ≤ 21MPa;
Unidirectional cut-off:A1 → A Reverse Cut offTo prevent high-pressure backflow;
DrainLeakage of oil in the spring chamberT-port leakageTo avoid back pressure affecting accuracy.
oil portP, T, A, B (A → A1 depressurization, T return oil)
InstallFixed with 4 bolts (NG06: M5; NG10: M6)
Dimensions (length x width x height):
ZDR6DA1: Approximately 70 × 40 × 45 mm
ZDR10DA1: Approximately 85 × 50 × 55 mm
Installation directionFrom any angle,T-port connected to fuel tank separately (back pressure ≤ 0.5MPa);
Stacking orderBottom plate → pressure reducing valve → directional valve → cover plate;
Pressure regulation steps:
Release the knob lock,Clockwise voltage increase, counterclockwise voltage decrease;
No load start, slowly increase the voltage to the targetLocking knob;
Key Attention:Excessive back pressure at the T-port can lead to inaccurate pressure regulation and drift.
Hydraulic stations, injection molding machines, machine tools, construction machinery, die-casting machines;
A-port branch pressure reduction, stabilization, and reverse cutoff protection;
andZDB stacked overflow valve, PVT hydraulic control one-way valvecoordination:Reduce pressure+maintain pressure+overload protection.
ZDR10DA1-40B/210YM, Stacked pressure reducing valve